CORROSION PROTECTION
Surface Preparation: Grit Blasting confirming to Swedish Standard Sa 2-1/2
Base Coat: Hot Zinc Spray Coating-120?
Primer Coat: High Build Zinc Phosphate Coating (2 Coats) -75?
Intermediate Coat: MIO (Micaceous Iron Oxide)-75?
Finish Paint: Epoxy Paint (2 Coats)- 100?
Total DFT of 370?
Expected Life: 25-30 Years
for C-4 Corrosive Category: ISO 12944(Highly Corrosive Atmosphere)
Advantage of Dual Painting System
Dual Paint System combine the barrier properties of coating with advantage of cathodic protection. If the zinc coating is scratched or otherwise locally damaged and steel is exposed, the surrounding areas of zinc coating form a galvanic cell with the exposed steel and protect it from corrosion. This is a form of localized cathodic protection – the zinc acts as a sacrificial anode.
APPLICATION OF TMSC
- Corrosion Protection
- Wear, Erosion & Abrasion Resistance Coating
- Chemical Resistance
- Repair & Dimension Restoration
- Thermal Barrier Coating
- Non-conductive Coating
- Conductive Coating
- Surface Traction
BROCHURES